BARIX · BARIONET FAMILY

Barionet 100

I/O device server with web server, Modbus/TCP and SNMP support. UL listed.

2003.9014 – Barionet 100 NoPSU Package
Barionet 100

Overview

Universal, programmable I/O device server with web server, Modbus/TCP and SNMP support. Serial ports, analog and digital I/O, Relays and Dallas 1-wire support. UL listed.

Technical Specifications

I/O2 relay outputs (240VAC 5A); 4 digital inputs (0-12V); 4 universal inputs (analog 0-5/10V or digital); 4 digital outputs (open collector 24V 0.1A); 2 Barix extension bus connectors with Dallas 1-Wire
Serial1 RS-232 (DSub-9 male RX/TX only); 1 RS-422/485 (2/4-wire); 600-19200 Baud
NetworkRJ45 10/100 Mbit Ethernet; TCP/IP UDP ICMP DHCP AutoIP IPzator XML SOAP Modbus/TCP SNMP CGI HTTP
Power9-30VDC 4W max
CaseHigh quality plastic 160g DIN-rail mount; 4.13x3.34x1.1 inch / 105x85x31mm
MTBFMin 205,000h (MIL217F at 25°C)

Protocols

TCP/IP, UDP, ICMP, DHCP, AutoIP, IPzator, XML, SOAP, Modbus/TCP, SNMP, CGI, HTTP

Power Requirements

9-30VDC, 4W max

Dimensions / Weight

4.13x3.34x1.1 inch / 105x85x31mm · 160g

MTBF

Min 205,000h (MIL217F at 25°C)

Real-World Scenarios

How Barionet 100 solves specific industry challenges.

1

UL-Listed Building Automation

A US commercial building project requires UL-listed I/O devices for HVAC and lighting control. Barionet 100's UL listing satisfies building code requirements, while its analog inputs monitor temperature sensors and relay outputs control HVAC zones — an IP-addressable building controller meeting US certification requirements.

2

Generator Status Monitoring

A data center needs remote monitoring of backup generator status (running, fuel level, fault). Barionet 100's analog inputs measure fuel level via a 4-20mA sensor, digital inputs monitor generator run status, and relay outputs can perform remote start — all accessible via Modbus TCP to the DCIM system.

3

Water Treatment Plant I/O Gateway

A water utility needs to connect legacy analog sensors (pH, flow) to an IP SCADA system. Barionet 100's analog+digital inputs bridge 4-20mA sensors to the IP network, making existing sensor infrastructure visible to the modern SCADA without replacing field hardware.

Ordering Numbers

  • 2003.9014 – Barionet 100 NoPSU Package
  • 2003.9032 – Barionet 100 NoPSU Package (OEM Package)

Accessories

  • 2004.9044 – X8 Extension
  • 2005.9048 – IO 12 Extension
  • 2004.9041 – Barix R6
View on BNA Barix Website

Enquire About This Product

For project consultancy, design engineering and commercials.